Watts 1 Inch Freeze Resistant Pressure Vacuum Breaker w/ Block Valves
Series 800M4FR1 Inch Freeze Resistant Anti-Siphon Pressure Vacuum Breaker Sizes 1/2" - 2" (15 - 50mm) Series 800M4FR is designed to prevent back-siphonage of contaminated water under continuous pressure into the potable water supply. Its superior design protects the valve body and internal components during sudden freeze conditions. Water inside the PVB freezes from the outside-inward. As the ice forms and expands, causing a buildup of pressure, the 800M4FR relieves the pressure through a unique relief valve built into the plastic float. Test cocks are positioned at the lowest point of the valve for winterization draining. The 800M4FR is reusable with the relief valve designed to automatically re-seat. It will not discharge through the relief valve during normal operation. (The built-in Features
Specifications A pressure anti-siphon vacuum breaker shall be installed where indicated on the plans to prevent the back-siphonage of contaminated water. This assembly is not to be used where there is a possibility that a back pressure condition may develop. The assembly will incorporate an acetal bonnet with silicone rubber O-ring seal and silicone rubber seat disc. The valve shall have replaceable seats. Check assembly shall be guided over its full stroke by ‘V’ notch guides. The assembly shall include an internal, built-in relief valve Materials
Models Prefix: U – union connections (3⁄4" - 1" only) Pressure - Temperature Temperature Range: 33°F to 140° (0.5°C to 60°C) Installations This valve is designed for installation in a continuous pressure potable water supply system 12" above the highest point of the downstream piping. The valve must be installed with the supply connected to the bottom and in a vertical position. Allow adequate space for periodic inspection, servicing or testing. The valve should not be installed in an area where freezing or spillage will cause damage. Adequate drainage/freeze protection must be provided in cold weather applications. 1.5psi (10 kPa) must be exerted against the float spring to seal the float and air inlet. Do not undersize supply and discharge piping. Important Note: Vacuum breakers are not designed, tested or approved to protect against backpressure backflow or water hammer shock. For protection against backpressure backflow, install Watts 909/009 Reduced Pressure Zone Backflow Preventer. For Protection against water hammer shock install a Watts Series 15 Water Hammer Arrestor utilizing good plumbing practice.
|
|
No posts found